                        March 22, 1985
HD-1481                                         Bulletin No:
Remote Coax Switch                              HD-1481-1

             Line Cord Wiring Doesn't Meet UL And CSA Requirements

In manual [PN 595-3189], page 19 and pictorial 2-2, the line cord wiring
instructions and pictorial are incorrect.  When the line cord is wired as
shown, the fuse will be in the ground [cold] side of the power line.  UL
and CSA require the fuse to be in the hot side of the line.  In the units
received for service, check the wiring of the line cord.  The correct
line cord wiring is the ribbed lead connected to TS1, lug 5 and the smoth
lead to TS-1, lug 4.
--------------------------------------------------------------------------------------------------------------------